Bk-249 | Am-245 | |
Cf-253 | Cm-249” |
(b) Insert „Ag-108m Ag-108” after: „Ru-106 Rh-106”.
Delete the entries for:
„Ce-134, La-134”;
„Rn-220, Po-216”;
„Th-226, Ra-222, Rn-218, Po-214”; and
„U-240, Np-240m”.
2.2.7.7.2.2 In the first sentence, delete:
„competent authority approval, or for international carriage;”.
Amend the beginning of the second sentence to read as follows:
„It is permissible to use an A2 value calculated using a dose coefficient for the appropriate lung absorption type as recommended by the International Commission on Radiological Protection, if the chemical forms of each radionuclide under both normal ... ”.
In the table:
- Amend the second entry in the first column to read:
„Alpha emitting nuclides but no neutron emitters are known to be present”.
- Amend the third entry in the first column to read:
„Neutron emitting nuclides are known to be present or no relevant data are available”.
2.2.7.8.4
(d) and (e) Add at the end:
„except undpr the provisions of 2.2.7.8.5”.
Add a new 2.2.7.8.5 to read:
„2.2.7.8.5 In case of international carriage of packages requiring competent authority design or shipment approval, for which different approval types apply in the different countries concerned by the shipment, assignment to the category as required in 2.2.7.8.4 shall be in accordance with the certifcate of the country of origin of design.”
2.2.7.9.7 Insert „Chapter 1.10” in the fist of provisions which do not apply.
2.2.8.1.6 Amend the beginning of the first sentence of the second paragraph to read as follows:
„Liquids, and solids which may become liquid during carriage, which are judged not to cause ... ” (remainder of the sentence unchanged).
2.2.8.3 Under classification code „C2”, amend the neme of UN 1740 to read as follows:
„HYDROGENDIFLUORIDES, SOLID, N.O.S.”
Under classifcation code „CF1”, add at the beginning:
„3470 PAINT, CORROSIVE, FLAMMABLE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or
3470 PAINT RELATED MATERIAL, CORROSIVE, FLAMMABLE (including paint thinning or reducing compound)”.
Under classification code „CT1”, add at the beginning:
„3471 HYDROGENDIFLUORIDES SOLUTION, N.O.S.”.
2.2.9.1.14 Replace „61 °C” with:
„60 °C”.
2.2.9.2 Amend the second indent to read as follows:
„- Uncleaned empty containment vessels for apparatus such as transformers, condensers and hydraulic apparatus containing substances assigned to UN Nos. 2315, 3151, 3152 or 3432.”
2.2.9.3 Under classification code „M8”, amend the name for UN 3245 to read as follows:
„GENETICALLY MODIFIED MICROORGANISMS or GENETICALLY MODIFIED ORGANISMS”.
2.3.3.1.7,
2.3.3.1.8 and
2.3.6 Figure Replace „61 °C” with:
„60 °C”.
3.1.2.2 and
3.1.2.3 Replace „consignment note” with:
„transport document”.
3.2.1 In the explanatory note for column (5), delete the second indent.
In the explanatory note for column (11), add the following NOTE at the end:
„NOTE: If technically relevant, these special provisions are not only applicable to the portable tanks specified in column (10), but also to the portable tanks that may be used according to the table in 4.2.5.2.5.”
In the explanatory note for column (13), add the following NOTE at the end:
„NOTE: If technically relevant, these special provisions are not only applicable to the tanks specified in column (12), but also to the tanks that may be used according to the hierarchies in 4.3.3.1.2 and 4.3.4.1.2.”
In the explanatory note for column (13), delete the Note in the first and third indents.
Table A
Amend Table A as follows:
Replace the code „LQ19” with „LQ7” wherever it is listed in Column (7), except in the case of UN 2809.
(applies to UN Nos. | 1556, | 1583, | 1591, | 1593, | 1597, | 1599, | 1602, | 1656, | 1658, | 1686, | |||
1710, | 1718, | 1719, | 1731, | 1755, | 1757, | 1760, | 1761, | 1783, | 1787, | 1788, | 1789, | 1791, | |
1793, | 1805, | 1814, | 1819, | 1824, | 1835, | 1840, | 1848, | 1851, | 1887, | 1888, | 1897, | 1902, | |
1903, | 1908, | 1935, | 1938, | 2021, | 2024, | 2030, | 2205, | 2206, | 2209, | 2225, | 2235, | 2269, | |
2272, | 2273, | 2274, | 2279, | 2289, | 2290, | 2294, | 2299, | 2300, | 2311, | 2320, | 2321, | 2326, | |
2327, | 2328, | 2431, | 2432, | 2433, | 2470, | 2491, | 2496, | 2501, | 2504, | 2511, | 2515, | 2518, | |
2525, | 2533, | 2564, | 2565, | 2580, | 2581, | 2582, | 2586, | 2609, | 2656, | 2661, | 2664, | 2667, | |
2669, | 2672, | 2677, | 2679, | 2681, | 2688, | 2689, | 2693, | 2730, | 2732, | 2735, | 2739, | 2747, | |
2753, | 2785, | 2788, | 2790, | 2801, | 2810, | 2815, | 2817, | 2818, | 2819, | 2820, | 2821, | 2829, | |
2831, | 2837, | 2849, | 2872, | 2873, | 2874, | 2902, | 2903, | 2904, | 2922, | 2937, | 2941, | 2942, | |
2946, | 2991, | 2992, | 2993, | 2994, | 2995, | 2996, | 2997, | 2998, | 3005, | 3006, | 3009, | 3010, | |
3011, | 3012, | 3013, | 3014, | 3015, | 3016, | 3017, | 3018, | 3019, | 3020, | 3025, | 3026, | 3055, | |
3066, | 3140, | 3141, | 3142, | 3144, | 3145, | 3172, | 3264, | 3265, | 3266, | 3267, | 3276, | 3278, | |
3280, | 3281, | 3282, | 3287, | 3293, | 3320, | 3347, | 3348, | 3351, | 3352, | 3410, | 3411, | 3413, | |
3414, | 3415, | 3418, | 3421, | 3422, | 3424, | 3426, | 3429, | 3434, | 3435 and 3440) |
Delete the code „TE15” wherever it is listed in Column (13).
In column (13), delete footnote * everywhere it appears in relation to special provisions „TU38” and „TE22”.
In column (13) insert „TE25” against ttre following entries:
- Tanks for gases of Class 2 with classification codes containing the letters T, TF, TC, TO, TFC or TOC,
- Tanks for substances of classes 3 to 8 with tank cade L15CH, L15DH or L21DH.
UN No. | Column | Amendment | |
1267, 1268 and 3295 | Delete the entries for which „640P” is assigned in column (6) | ||
1267, 1268 and 3295 | 6 | For each entry that is currently assigned „640A” in column (6), insert: „649”. | |
1133, 1139, 1189, 1197, 1210, 1263, 1266, 1267, 1268, 1286, 1287, 1308, 1863, 1866, 1989, 1993, 2059 and 3295 | 2 | Delete „(vapour pressure at 50 °C more than 175 kPa)” for each entry that is assigned „640A” in column (6). | |
6 | Delete „640A” for each entry that is assigned „640A” in column (6). | ||
1133, 1139, 1169, 1197, 1210, 1263, 1266, 1267, 1268, 1286, 1287, 1308, 1863, 1866, 1989, 1993, 2059 and 3295 | Delete the entries for which „6408” is assigned in column (6). | ||
1133, 1139, 1169, 1197, 1210, 1224, 1263, 1266, 1267, 1268, 1286, 1287, 1306, 1308, 1883, 1866, 1987, 1989, 1993, 1999, 3295 and 3336 | 2 | Delete „but not more than 175 kPa” for each entry that is assigned „640C” in column (6). | |
1133, 1139, 1169, 1197, 1210, 1263, 1266, 1266, 1287, 1306, 1866, 1993 and 1999 | 2 | For each entry that is assigned „640F” in column (6) replace „vapour pressure at 50 °C more than 175 kPa” with „boiling point not more than 35 °C”. | |
1133, 1139, 1169, 1197, 1210, 1263, 1266, 1286, 1287, 1306, 1866, 1993 and 1999 | 2 | For each entry that is assigned „640G” in column (6) replace „but not more than 175 kPa” with „boiling point of more than 35 °C”. | |
UN No. | Column | Amendment | |
0015 | 6 | Delete: „204”. | |
0016 | 6 | Delete: „204”. | |
0303 | 6 | Delete: „204”. | |
1013 | 6 | Add: „653”. | |
1014 | 1-20 | Delete the whole entry. | |
1015 | 1-20 | Delete the whole entry. | |
1143 | 2 | Amend the name to read as follows: „CROTONALDEHYDE or CROTONALDEHYDE, STABILIZED”. | |
6 | Add „324”. | ||
1155 | 12 | Replace „L1.5BN” with; „L4BN”. | |
1167 | 12 | Replace „L1.5BN” with: „L4BN”. | |
1169, PG II and III | 6 | Insert: „601” (six times). | |
1170, PG II and III | 6 | Insert: „330 601” (twice). | |
9 | Delete: „PP2” (twice). | ||
1197, PG II and III | 6 | Insert: „601” (six times). | |
1202 (first and third entry) | 2 | Replace „61 °C” with: „60 °C”. | |
1202 (second entry) | 2 | Replace „EN 590:1993” with: „EN 590:2004” (twice). | |
1203 | (9a) | Insert „BB2” adjacent to „IBC02” in column (8). | |
1218 | 12 | Replace „L1.5BN” with: „L4BN”. | |
1219 | 6 | Insert: „601”. | |
1263, VG I | 11 | Add: „TP27”. | |
1263, VG II | 11 | Add: „TP28” (twice). | |
1263, VG III | 11 | Add: „TP29” (twice). | |
1280 | 12 | Replace „L1.5BN” with: „L4BN”. | |
1293, PG II and III | 6 | Insert: „601” (twice). | |
1302 | 12 | Replace „L1.58N” with: „L4BN”. | |
1366 | 1-20 | Delete the whole entry. | |
1370 | 1-20 | Delete the whole entry. | |
1391 | 2 | Add, at the end: „having a flash-point above 60 °C”. | |
6 | Delete: „282„ | ||
1463 | 3b | Replace „OC2” with: „OTC”. | |
5 | Replace „5.1 + 8” with: „5.1 + 6.1 + 8”. | ||
16 | Insert: „W11 W12”. | ||
18 | After „CW24”, add: „CW28”. | ||
20 | Replace „58” with: „568”. | ||
1614 | 8 | Insert before „P601„: „PO99”. | |
1649 | 2 | Add, at the end: „having a flash-point above 60 °C”. | |
6 | Delete: „162”. | ||
1733 | 10 | Insert: „T3”. | |
11 | Insert: „TP33”. | ||
1740 | 2 | Amend the name to read as follows: „HYDROGENDIFLUORIDES SOLID N.O.S,” (twice). | |
1779 | 2 | Amend the name to read as follows: „FORMIC ACID with more than 85% acid by mass”. | |
3b | Replace „C3” with; „CF1”. | ||
5 | After „8”, add; „+3”. | ||
20 | Replace „80” with: „83”. | ||
1848 | 2 | Amend the name to read as follows: „PROPIONIC ACID with not less than 10% and less than 90% acid by mass”. | |
1950 | 6 | After „190”, insert: „327” (twelve times). | |
8 | Replace „P204” with: „P003 LP02” (twelve times). | ||
9a | Insert: „PP17 PP87 RR6 L2” (twelve times). | ||
16 | Insert: „W14”. | ||
1956 | 6 | After „274”, insert: „292”. | |
1979 | 1-20 | Delete the whole entry. | |
1980 | 1-20 | Delete the whole entry. | |
1981 | 1-20 | Delete the whole entry. | |
1987 PG I and III | 6 | Insert: „330 601” (three times). | |
1993 PG I, II and III | 6 | Insert: „330” (seven times). | |
1993, PG II and III | 6 | Insert: „601” (six times). | |
2005 | 1-20 | Delete the whole entry. | |
2015 | 10 | Replace „T10” with: „T9” (twice). | |
2030 | 2 | Add, at the end: „having a flash-point above 60 °C” (three times). | |
6 | Delete: „298” (three times). | ||
2030, PG I | 10 | Replace „T20” with: „T10”. | |
2030, PG II | 10 | Replace „T15” with: „T7”. | |
2030, PG III | 11 | Replace „TP2” with: „TP1”. | |
2037 | 8 | Replace „P204„’ with: „P003” (nine times). | |
9a | Add: „PP17 RR6” (nine times). | ||
2356 | 12 | Replace „L1.5BN” with: „L4BN”. | |
2363 | 12 | Replace „L1.5BN” with: „L4BN”. | |
2445 | 1-20 | Delete the whole entry. | |
2600 | 1-20 | Delete the whole entry. | |
2662 | 1-20 | Delete the whole entry. | |
2814 | 6 | Delete: „634”. | |
2823 | 2 | Amend the name to read as follows: „CROTONIC ACID SOLID”. | |
2880, PG II | 6 | Add: „322”. | |
2880, PG III | 6 | Replace „316” with: „313 314”. | |
2900 | 6 | Delete: „634”. | |
10 | Delete: „BK1 BK2”. | ||
2912 | 6 | Add: „325”. | |
2915 | 6 | Add: „325”. | |
3051 | 1-20 | Delete the whole entry. | |
3052 | 1-20 | Delete the whole entry. | |
3053 | 1-20 | Delete the whole entry. | |
3066, PG II | 11 | Add: „TP28”. | |
3066, PG III | 11 | Add: „TP29”. | |
3076 | 1-20 | Delete the whole entry. | |
3077 | 6 | Insert: „601”. | |
3082 | 6 | Insert: „601”. | |
3175 | 2 | Replace „61 °C” with: „60 °C”. | |
3245 | 2 | Amend the name to read as follows: „GENETICALLY MODIFIED MICROORGANISMS or GENETICALLY MODIFIED ORGANISMS”. | |
6 | Delete: „634”. | ||
3256 | 2 | Replace „61 °C” with: „60 °C”. | |
13 | Delete: „TE24”. | ||
3257 | 13 | Delete: „TE24”. | |
3272, PG II and III | 6 | Insert: „601” (twice). | |
3291 | 6 | Delete: „634”. | |
10 | Add: „BK2”. | ||
3321 | 6 | Add: „325”. | |
3322 | 6 | Add: „325”. | |
3324 | 6 | Add: „326”. | |
3325 | 8 | Add: „326„ | |
3327 | 6 | Add: „326”. | |
3336 | 12 | Replace „L1.5BN” with: „L4BN”. | |
3364, 3365, 3366, 3367, 3368, 3370 | 2 | Replace „wetted” with: „WETTED”. | |
3373 | 2 | Amend the name to read as follows: „BIOLOGICAL SUBSTANCE, CATEGORY B”. | |
5 | Insert: „6.2”. | ||
10 | Insert: „T1.”. | ||
11 | Insert: „TP1”. | ||
3375, liquid | 13 | Delete: „TU26’”. | |
3375, solid | 13 | Delete: „TU26”. | |
3433 | 1-20 | Delete the whole entry. | |
3435 | 1-20 | Delete the whole entry. | |
3461 | 1-20 | Delete the whole entry. |
Add the following new entries:
Packaging | Portable tanks and bulk containers | RID tanks | Special provisions for carriage | ||||||||||||||||||||
Un No. | Name and description | Class | Clas- sifi- cation code | Pac- king gruop | La- bels | Spe- cial pro- visi- ons | Limi- ted quan- titites | Pac- king in- druc- tions | Spe- cial pac- king pro- visi- ons | Mi- xed pack. pro- visi- ons | Inst- ruc- tions | Spe- cial pro- visi- ons | Tank code | Spe- cial pro- visi- ons | Ve- hicle for tank carri- age (ADR) | Tran- sport cate- gory | Pac- kages | Bulk | Load- ing, un- load- ing and handl-ing | Ope- ration (ARD) | Colis ex- pres | Ha- zard iden- tificat ion No. | |
(1) | (2) | (3a) | (3b) | (4) | (5) | (6) | (7) | (8) | (9a) | (9b) | (10) | (11) | (12) | (13) | (14) | (15) | (16) | (17) | (18) | (19) | (19) | (20) | |
0015 | AMMUNITION, SMOKE with or without burster, expelling charge or propelling charge, containing corrosive substances | 1 | 1.2G | 1+8 | LQ0 | P130 LP 101 | PP67 L1 | MP23 | 1 | W2 | CW1 | 1.2G | |||||||||||
0016 | AMMUNITION, SMOKE with or without burster, expelling charge or propelling charge, containing corrosive substances | 1 | 1.3G | 1+8 | LQ0 | P130 LP 101 | PP67 L1 | MP23 | 1 | W2 | CW1 | 1.3G | |||||||||||
0303 | AMMUNITION, SMOKE with or without burster, expelling charge or propelling charge, containing corrosive substances | 1 | 1.4G | 1.4+8 | LQ0 | P130 LP 101 | PP67 L1 | MP23 | 2 | W2 | CW1 | 1.4G | |||||||||||
1391 | ALKALI METAL DISPERSION or ALKALINE EARTH METAL DISPERSION having a flash-point of not more than 60 °C | 4.3 | WF1 | 1 | 4.3+3 | 182 183 274 506 | LQ0 | P402 PR1 | MP2 | L10 BN (+) | TU1 TE5 TT3 TM2 | 1 | W1 | CW 23 | X323 | ||||||||
1649 | MOTOR FUEL ANTI-KNOCK MIXTURE having a flash- point of not more than 60 °C | 6.1 | TF1 | 1 | 6.1+3 | LQ0 | P602 | MP8 MP17 | T14 | TP2 | L10 CH | TU14 TU15 TU38 TE21 TE22 TT6 | 1 | CW 13 CW 28 CW 31 | 663 | ||||||||
2030 | HYDRAZINE AQUEOUS SOLUTION, with more than 37% hydrazine by mass having a fiash-point of not more than 60 °C | 8 | CFT | 1 | 8+6.1+3 | 530 | LQ0 | P001 | MP8 MP17 | T10 TP2 | L10 BH | TU38 TE22 | 1 | CW 13 CW 28 | 886 | ||||||||
2814 | INFECTIOUS SUBSTANCE, AFFECTING HUMANS, in refrigerated liquid nitrogen | 6.2 | I1 | 6.2+ 2.2 | 318 | LQ0 | P620 | MP5 | 0 | W9 | CW 13 CW 18 CW 26 CW 28 | CE14 | 606 | ||||||||||
2814 | INFECTIOUS SUBSTANCE, AFFECTING HUMANS (animal carcasses only) | 6.2 | I1 | 6.2 | 318 | LQ0 | P099 P620 | MP5 | BK1 BK2 | 0 | W9 | CW 13 CW 18 CW 26 CW 28 | CE14 | 606 | |||||||||
2900 | INFECTIOUS SUBSTANCE, AFFECTING ANIMALS only, in refrigerated liquid nitrogen | 6.2 | I2 | 6.2+ 2.2 | 318 | LQ0 | P620 | MP5 | 0 | W9 | CW 13 CW 18 CW 26 CW 28 | CE14 | 606 | ||||||||||
2900 | INFECTIOUS SUBSTANCE, AFFECTING ANIMALS only (animal carcasses and wastes only) | 6.2 | I2 | 6.2 | 318 | LQ0 | P099 P620 | MP5 | BK1 BK2 | 0 | W9 | CW 13 CW 18 CW 26 CW 28 | CE14 | 606 | |||||||||
3245 | GENETICALLY MODIFIED MICROORGANISMS or GENETICALLY MODIFIED ORGANISMS, in refigerated liquid nitrogen | 9 | M8 | 9+2.2 | 219 637 | LQ0 | P904 IBC 08 | MP6 | 2 | CW 13 C17 CW 18 CW 26 GW 28 CW 31 | 90 | ||||||||||||
3291 | CLINICAL WASTE, UNSPECIFIED, N.O.S. or (BIO) MEDICAL WASTE, N.O.S. or REGULATED MEDICAL WASTE, N.O.S., in refrigerated liquid nitrogen | 6.2 | I3 | II | 6.2+ 2.2 | 565 | LQ0 | P621 IBC 620 LP 621 | MP6 | 2 | W9 | CW 13 CW 18 CW 28 | CE14 | 606 | |||||||||
3412 | FORMIC ACID with not less than 10% but not more than 85% acid by mass | 8 | C3 | II | 8 | LQ22 | P001 IBC 02 | MP15 | T7 | TP2 | L4BN | 2 | CE6 | 80 | |||||||||
3412 | FORMIC ACID with not less than 5% but less than 10% acid by mass | 8 | C3 | III | 8 | LQ7 | P001 IBC 03 LP01 R001 | MP15 | T4 | TP1 | L4 BN | 3 | CE6 | 80 | |||||||||
3463 | PROPIONIC ACID with not less than 90% acid by mass | 8 | CF1 | II | 8+3 | LQ22 | P001 IBC02 | MP15 | T7 | TP2 | L4 BN | 2 | CE6 | 83 | |||||||||
3469 | PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL, FLAMMABLE, CORROSIVE (including paint thinning or reducing compound) | 3 | FC | I | 3+8 | 163 | LQ3 | P001 | MP7 MP17 | T11 | TP2 TP27 | L10 CH | TU14 TU38 TE21 TE22 | 1 | 338 | ||||||||
3469 | PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL, FLAMMABLE, CORROSIVE (including paint thinning or reducing compound) | 3 | FC | II | 3+8 | 163 | LQ4 | P001 IBC 02 | MP19 | T7 | TP2 TP8 TP8 | L48H | 2 | CE7 | 338 | ||||||||
3469 | PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAI, FLAMMABLE, CORROSIVE (including paint thinning or reducing compound) | 3 | FC | III | 3+8 | 163 | LQ7 | P001 IBC 03 R001 | MP19 | T4 | TP1 TP29 | L48H | 2 | CE4 | 38 | ||||||||
3470 | PAINT, CORROSIVE, FLAMMABLE (incliding paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAI, CORROSIVE, FLAMMABLE (including paint thinning or reducing compound) | 8 | CF1 | II | 8+3 | 163 | LQ22 | P001 IBC 02 | MP15 | T7 | TP2 TP8 TP28 | L4 BN | 2 | CE6 | 83 | ||||||||
3471 | HYDROGENDI- FLUORIDES SOLUTION, N.O.S. | 8 | CT1 | II | 8+6.1 | LQ22 | P001 IBC 02 | MP15 | T7 | TP2 | L4 DH | TU14 TE17 TE21 TT4 | 2 | CW 13 CW 28 | CE6 | 86 | |||||||
3471 | HYDROGENDI- FLUORIDES SOLUTION, N.O.S. | 8 | CT1 | III | 8+6.1 | LQ7 | P001 IBC 03 R001 | MP15 | T4 | TP1 | L4 DH | TU14 TE21 | 3 | CW 13 CW 28 | CE8 | 86 | |||||||
3472 | CROTONIC ACID, LIQUID | 8 | C3 | III | 8 | LQ7 | P001 IBC 03 LP01 R001 | MP15 | T4 | TP1 | L4 BN | 3 | CE8 | 80 | |||||||||
3473 | FUEL CELL CARTRIDGES containing flammable liquids | 3 | F1 | 3 | 328 | LQ13 | P003 | PP88 | 3 | CE7 | 30 |
Table B
Name and description | UN No. | Amendment | |
ALUMINIUM ALKYLS | 3051 | Delete. | |
ALUMINIUM ALKYL HALIDES, SOLID | 3461 | Delete. | |
ALUMINIUM ALKYL HALIDES, LIQUID | 3052 | Delete. | |
ALUMINIUM ALKYL HIDRIDES | 3076 | Delete. | |
CARBON DIOXIDE AND NITROUS OXIDE MIXTURE | 1015 | Delete. | |
CARBON DIOXIDE AND OXYGEN MIXTURE, COMPRESSED | 1014 | Delete. | |
CARBON MONOXIDE AND HYDROGEN MIXTURE, COMPRESSED | 2600 | Delete. | |
CLINICAL SPECIMENS | 3373 | Delete. | |
CROTONIC ACID | 2823 | Amend the name to read as follows: „CROTONIC ACID SOLID”. | |
DIAGNOSTIC SPECIMENS | 3373 | Amend the name to read as follows: „BIOLOGICAL SUBSTANCE, CATEGORY B”. | |
DIETHYLZINC | 1366 | Delete. | |
DIMETHYLZINC | 1370 | Delete. | |
ELEVATED TEMPERATURE LIQUID, FLAMMABLE, N.O.S. with flash-point above 61 °C, at or above its flash-point | 3256 | Replace „61 °C” with: „60 °C”. | |
Fischer Tropsch gas: see | 2600 | Delete. | |
FORMIC ACID | 1779 | Amend the name to read as follows: „FORMIG ACID with more than 85% acid by mass”. | |
GENETICALLY MODIFIED MICRO-ORGANISMS | 3245 | Amend the name to read as follows: „GENETICALLY MODIFIED MIGROORGANISMS”. In Column „NHM-Code” replace „051199” with: „300290”. | |
GENETICALLY MODIFIED ORGANISMS | In Column „UN No.”, insert: „3245”. | ||
HYDROGENDIFLUORIDES, N.O.S. | 1740 | Amend the name to read as follows: „HYDROGENDIFLUORIDES, SOLID N.O.S.”. | |
HYDROQUINONE, SOLID | 2662 | Delete. | |
HYDROQUINONE SOLUTION | 3435 | Delete. | |
LITHIUM ALKYLS, SOLID | 3433 | Delete. | |
LITHIUM ALKYLS, LIQUID | 2445 | Delete. | |
MAGNESIUM ALKYLS | 3053. | Delete. | |
MAGNESIUM DIPHENYL | 2005 | Delete. | |
Mixtures of solids containing flammable liquid, n.o.s. having a flash-point up to 61 °C | 3175 | Replace „61 °C” with: „60 °C”. | |
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) | 1263 | In Column „NHM-Code”, delete: °381400”. | |
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) | 3066 | In Column „NHM-Code”, delete: „381400”. | |
PAINT RELATED MATERIAL (including paint thinning or reducing compound) | 1263 | In Calumn „NHM-Code”, delete: „3208++”. | |
PAINT RELATED MATERIAL (including paint thinning or reducing compound) | 3066 | In Column „NHM-Code”, delete: „3208++”. | |
PICRIC ACID wetted with not less than 10% water, by mass | 3364 | Replace „wetted” with: „WETTED”. | |
PICRYL CHLORIDE wetted with not less than 10% water, by mass | 3365 | Replace „wetted” with: „WETTED”. | |
Preparations containing flammable liquid, n.o.s. having a flash-point up to 61 °C | 3175 | Replace „61 °C” with: „60 °C”. | |
PROPIONIC ACID | 1848 | Amend the name to read as follows: „PROPIONIC ACID with not less than 10% and less than 90% acid by mass”. | |
RARE GASES AND NITROGEN MIXTURE COMPRESSED | 1981 | Delete. | |
RARE GASES AND OXYGEN MIXTURE COMPRESSED | 1980 | Delete. | |
RARE GASES, MIXTURE, COMPRESSED | 1979 | Delete. | |
SOLIDS CONTAINING FLAMMABLE LIQUID, N.O.S. having a flash-point up to 61 °C | 3175 | Replace „”61 °C” with: „60 °C”. | |
Synthesis gas: see | 2600 | Delete. | |
TNT, wetted with not less than 10% water, by mass | 3366 | Replace „wetted” with: „WETTED”. | |
TRINITROBENZENE, wetted with not less than 10% water, by mass | 3367 | Replace „wetted” with: „’WETTED”. | |
TRINITROBENZOIC ACID, wetted with not less than 10% water, by mass | 3368 | Replace „wetted” with: „WETTED”. | |
TRINITROGHLOROBENZENE wetted with not less than 10% water, by mass | 3365 | Replace „wetted” with: „WETTED”. | |
TRINITROPHENOL wetted with not less than 10% water, by mass | 3364 | Replace „wetted” with: „WETTED”. | |
TRINITROTOLUENE, wetted with not less than 10% water, by mass | 3366 | Replace „wetted” with: „’WETTED”. | |
UREA NITRATE, wetted with not less than 10% water, by mass | 3370 | Replace „wetted” with: „WETTED”. | |
Wastes containing flammable liquid, n.o.s. having a flash-point up to 61 °C | 3175 | Replace „61 °C” with: „60 °C”. | |
Water gas: see | 2600 | Delete. |
Add the following new entries:
Name and description | UN No. | Note | NHM-Code | |
CROTONALDEHYDE | 1143 | 291219 | ||
CROTONIC ACID, LIQUID | 3472 | 291619 | ||
FORMIC ACID with not less than 10% but not more than 85% acid by mass | 3412 | 291511 | ||
FUEL CELL CARTRIDGES containing flammable liquids | 3473 | 850680 | ||
HYDROGENDIFLUORIDES SOLUTION, N.O.S. | 3471 | 282619 | ||
PAINT, CORROSIVE, FLAMMABLE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) | 3470 | 3208++ | ||
PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) | 3469 | 3208++ | ||
PAINT RELATED MATERIAL, CORROSIVE, FLAMMABLE (including paint thinning or reducing compound) | 3470 | 381400 | ||
PAINT RELATED MATERIAL, FLAMMABLE, CORROSIVE (including point thinning or reducing compound) | 3469 | 381400 | ||
PROPIONIC ACID with not less than 90% acid by mass | 3463 | 291550 |
3.3.1
SP 250 (b),
SP 318,
SP 581,
SP 582,
SP 583,
SP 640 and
SP 650 (e) Replace „consignment note” with:
„transport document”.
SP 162 Replace current text with:
„(Deleted)”.
SP 181 Insert „(see 5.2.2.2.2) „after „model No.1”.
SP 204 Replace current text with:
„(Deleted)”.
SP 216 In the last sentence, insert „and articles” before „containing” and amend the end to read: ”... free liquid in the packet or article.”
SP 247 Amend the end of the first paragraph to read:
”... may be carried in wooden barrels with a capacity of more than 250 litres and not more than 500 litres meeting the general requirements of 4.1.1, as appropriate, on the following conditions: ...”.
Replace the word „casks” with „wooden barrels” (5 times).
SP 251 In the first sentence, add „for example” before „for medical,” add „or repair” before „purposes”.
SP 282 Replace current text with:
„(Deleted)”.
SP 289 Replace „vehicles” and „vehicle” with „conveyances” and „conveyance”, respectively.
SP 292 Amend to read as follows:
„Mixtures containing not more than 23.5% oxygen by volume may be carried under this entry when no other oxidizing gases are present. A label conforming to model 5.1 is not required for any concentrations within this limit.”
SP 298 Replace current text with:
„(Deleted)”.
SP 303 Amend to read as follows:
„Receptacles shall be assigned to the classification code of the gas or mixture of gases contained therein determined in accordance with the provisions of section 2.2.2.”
SP 309 Amend to read as follows:
„This entry applies to nan sensitized emulsions, suspensions and gels consisting primarily of a mixture of ammonium nitrate and fuel, intended to produce a Type E blasting explosive only after further processing prior to use.
The mixture for emulsions typically has the following composition: 60-85% ammonium nitrate, 5-30% water, 2-8% fuel, 0.5-4% emulsifier agent, 0-10% soluble flame suppressants, and trace additives. Other inorganic nitrate salts may replace part of the ammonium nitrate.
The mixture for suspensions and gels typically has the following composition: 60-85% ammonium nitrate, 0-5% sodium or potassium perchlorate, 0-17% hexamine nitrate or monomethylamine nitrate, 5-30% water, 2-15% fuel, 0.5-4% thickening agent, 0-10% soluble flame suppressants, and trace additives. Other inorganic nitrate salts may replace part of the ammonium nitrate.
Substances shall satisfactarily pass Test Series 8 of the Manual of Tests and Criteria, Part I, Section 18 and be approved by the competent authority.”.
SP 316 Delete „or hydrated”.
SP 319 Delete the first sentence.
SP 320 Amend to read as follows:
„(Deleted)”,
„322-499 (Reserved)” becomes:
„331-499 (Reserved)”.
SP 601 Amend to read as follows:
„Pharmaceutical products (medicines) ready for use, which are substances manufactured and packaged for retail sale or distribution for personal or household consumption are not subject to the requirements of RID.”
SP 617 Delete:
„and shall be specified in the consignment note”.
SP 633 Amend „unless any international tariffs or agreements between the railways provide otherwise” to read:
„unless any agreements concluded between the countries concerned in the transport operation provide otherwise”.
SP 634 Amend to read as follows:
„(Deleted)”.
SP 645 Add the following new sentence at the end:
„When assignment to a division is made in accordance with the procedure in 2.2.1.1.7.2, the competent authority may require the default classification to be verified on the basis of test data derived from Test Series 6 of the Manual of Tests and Criteria, Part I, Section 16.”
SP 649 Delete the address in footnote 2.
Add the following new special provisions:
„322 When carried in non-friable tablet form, these goods are assigned to packing group III.
323 (Reserved)
324 This substance needs to be stabitized when in concentrations of not more than 99%.
325 In the case of non-fissile or fissile excepted uranium hexafluoride, the material shall be classified under UN No. 2978.
326 In the case of fissile uranium hexafluoride, the material shall be classified under UN No. 2977.
327 Waste aerosols consigned in accordance with 5.4.1.1.3 may be carried under this entry for the purposes of reprocessing or disposal. They need nat be protected against inadvertent discharge provided that measures to prevent dangerous build up of pressure and dangerous atmospheres are addressed. Waste aerosols, other than those leaking or severely deformed, shall be packed in accordance with packing instruction P003 and special provision PP87, or packing instruction LP02 and special packing provision L2. Leaking or severely deformed aerosols shall be carried in salvage packagings provided appropriate measures are taken to ensure there is no dangerous build up of pressure.
NOTE: For maritime carriage, waste aerosols shall not be carried in closed containers.
328 This entry applies to fuel cell cartridges containing flammable liquids including methanol or methanol/water solutions. Fuel cell cartridge means a container that stores fuel for discharge into fuel cell powered equipment through a valve(s) that controls the discharge of fuel into such equipment and is free of electric charge generating components. The cartridge shall be designed and constructed to prevent the fuel from leaking during normal conditions of carriage.
This entry applies to fuel cell cartridge design types shown without their packaging to pass an internal pressure test at a pressure of 100 kPa (gauge).
329 (Reserved)
330 Alcohols containing petroleum products (e.g. gasoline) up to 5% shall be carried under the entry UN 1987 ALCOHOLS, N.O.S.
653 The carriage of this gas in cylinders with a maximum capacity of 0.5 litres, is not subject to the other provisions of RID if the following conditions are met:
- The provisions for construction and testing of cylinders are observed;
- The cylinders are contained in outer packagings which at least meet the requirements of Part 4 for combination packagings. The general provisions of packing of 4.1.1.1, 4.1.1.2 and 4.1.1.5 to 4.1.1.7 shall be observed;
- The cylinders are not packed together with other dangerous goods;
- The total gross mass of a package does not exceed 30 kg; and
- Each package is clearly and durably marked with „UN 1013”. This marking is displayed within a diamond-shaped area surrounded by a line that measures at least 100 mm by 100 mm.”
3.4.6 In the first column of table 3.4.6 replace „LQ4” and „LQ5” with „LQ4” and „LQ5” respectively,
In the table, for LQ19, replace respectively „3 /” and „1 /” with „5 kg”.
4.1.1.2 In the Note, delete „high and medium molecular mass”.
4.1.1.3 Replace „6.5.4” with:
„6.5.6”.
4.1.1.5 Insert the following new second sentence:
„Inner packagings containing liquids shall be packed with their closures upward and placed within outer packagings consistent with the orientation markings prescribed in 5.2.1.9.”
4.1.1.5.1 Insert a new paragraph 4.1.1.5.1 with the same text as in existing 6.1.5.1.6 with the insertion of the words „or a large packaging” after „combination packaging” and the words „or large packaging” after „outer packaging” in the first sentence.
4.1.1.8 Amend to read as follows:
„4.1.1.8 Where pressure may develop in a package by the emission of gas from the contents (as a result of temperature increase or other causes), the packaging or IBC may be fitted with a vent provided that the gas emitted will not cause danger on account of its toxicity, its ftammability or the quantity released, far example.
A verting device shall be fitted if dangerous overpressure may develop due to normal decomposition of substances. The vent shall be so designed that, when the packaging or IBC is in the attitude in which it is intended to be carried, leakages of liquid and the penetration of foreign substances are prevented under normal conditions of carriage.
NOTE: Verting of the package is not permitted for air carriage.
4.1.1.8.1 Liquids may only be filled into inner packagings which heve an appropriate resistance to internal pressure that may be developed under honnal conditions of carriage.”
4.1.1.9 Replace „6.5.4” with:
„6.5.6”.
4.1.1.12 In the first sentence, replace ”, including IBCs,” with „as specified in Chapter 6.1” and delete”, or 6.5.4.7 for the various types of IBCs”.
Delete (c).
In the lest paragraph, delete”, or IBC,” in the first sentence and „or IBC” in the second sentence.
4.1.1.18.1 Add at the end:
„and 4.1.1.18.3”.
Add a new paragraph to read as follows:
„4.1.1.18.3 Appropriate measures shall be taken to ensure that there is no dangerous build up of pressure.”
4.1.1.19.1 In the first sentence, delete „high and medium molecular mass” and „high molecular mass”.
In the first sentence, replace „6.5.4.3.5” with:
„6.5.6.3.5”.
In the first sentence, replace „6.5.4” with:
„6.5.6”.
In the second sentence, replace „6.5.4.3.3 or 6.5.4.3.6” with:
„6.5.6.3.3 or 6.5.6.3.6”.
4.1.1.19.2 Replace „6.5.4.1.3” with:
„6.5.6.9.4”.
Replace „6.5.4.6” with:
„6.5.6.6”.
Replace „6.5.4.8.4.2” with:
„6.5.6.8.4.2”.
4.1.1.19.3 (c) and (d) Replace „6.5.4.3.3 or 6.5.4.3.6” with:
„6.5.6.3.3 or 6.5.6.3.6”.
4.1.1.19.6 Make the following modifications in Column (2b) of the Table:
- For UN numbers 1198, 1760, 1835, 1920, 2324, 2357, 2394, 2617, 2620, 2656, 2683, 2850, 2920 (three times), 2922, 3082 (seven times), 3264, 3265, 3266, 3267 and 3271, replace „61 °C” with:
„60 °C”.
- For UN No. 1202, replace „EN 590:1993” with:
„EN 590:2004” (twice).
- Amend the name for UN No. 1779 to read as follows:
„FORMIC ACID with more than 85% acid by mass”.
- In the table, in Note * to UN No. 1791, replace „For hypochlorite solutions” with:
„If the test is carried aut with hypochlorite solutions themselves”.
- Amend the name for UN No. 1848 to read as follows:
„PROPIONIC ACID with not less than 10% and less than 90% acid by mass”.
4.1.2.1 Replace „61 °C” with:
„60 °C”.
4.1.2.2 Replace the first sentence with the following paragraph:
„Every metal, rigid plastics and composite IBC, shall be inspected and tested, as relevant, in accordance with 6.5.4.4 or 6.5.4.5.
(a) before it is put into service;
(b) thereafter at intervals not exceeding two and a half and five years, as appropriate;
(c) after the repair or remanufacture, before it is re-used for carriage.”
Amend the end of the second sentence (starting with „An IBC shall not be filled ... ”) to read as follows: ”... expiry of the last periodic test or inspection.”
In the Note, replace „consignment note” with:
„transport document”.
4.1.3.6 Amend to read as follows:
„4.1.3.6 Pressure receptacles for liquids and solids
4.1.3.6.1 Unless otherwise indicated in RID, pressure receptacles conforming to:
(a) the applicable requirements of Chapter 6.2 or
(b) the national or international standards on the design, construction, testing, manufacturing and inspection, as applied by the country in which the pressure receptacles are manufactured, provided that the provisions of 4.1.3.6 are met and that, for metallic cylinders, tubes, pressure drums and bundies of cylinders, the construction is such that the minimum burst ratio (burst pressure divided by test pressure) is:
(i) 1.50 for refillable pressure receptacles;
(ii) 2.00 for non-refillable pressure receptacles;
are authorized for the carriage of any liquid or solid substance other than explosives, thermally unstable substances, organic peroxides, self-reactive substances, substances where significant pressure may develop by evolution of chemical reaction and radioactive material (unless permitted in 4.1.9).
This sub-section is not applicable to the substances mentioned in 4.1.4.1, packing instruction P200, table 3 and in 4.1.4.4.
4.1.3.6.2 Every design type of pressure receptacle shall be approved by the competent authority of the country of manufacture or as indicated in Chapter 6.2.
4.1.3.6.3 Unless otherwise indicated, pressure receptacles having a minimum test pressure of 0.6 MPa shall be used.
4.1.3.6.4 Unless otherwise indicated, pressure receptacles may be provided with an emergency pressure relief device designed to avoid bursting in case of overfill or fire accidents.
Pressure receptacle valves shall be designed and constructed in such a way that they are inherently able to withstand damage without release of the contents or shall be protected from damage which could cause inadvertent release of the contents of the pressure receptacle, by one of the methods as given in 4.1.6.8 (a) to (f).
4.1.3.6.5 The level of filling shall not exceed 85% of the capacity of the pressure receptacle at 50 °C. Sufffcient ullage (outage) shall be left to ensure that the pressure receptacle will not be liquid full at a temperaturu of 55 °C.
4.1.3.6.6 Unless otherwise indicated pressure receptacles shall be subjected to a periodic inspection and test every 5 years. The periodic inspection shall include an external examination, an internal examination or altemative method as approved by the competent authority, a pressure test or equivalent effective non-destructive testing with the agreement of the competent authority including an inspection of all accessories (e.g. tightness of valves, emergency relief valves or fusible elements). Pressure receptacles shall not be filled after they become due for periodic inspection and test but may be carried after the expiry of the time limit. Pressure receptacle repairs shall meet the requinements of 4.1.6.11.
4.1.3.6.7 Prior to filling, the packer shall perform an inspection of the pressure receptacle and ensure that the pressure receptacle is authorized for the substances to be carried and that the requirements of RID have been met. Shut-off valves shall be closed after filling and remain closed during carriage. The consignor shall verify that the closures and equipment are not leaking.
4.1.3.6.8 Refillable pressure receptacles shall not be filled with a substance different from that previously contained unless the necessary operations for change of service heve been performed.
4.1.3.6.9 Marking of pressure receptacles for liquids and solids according to 4.1.3.6 (not conforming to the requirements of Chapter 6.2) shall be in accordance with the requirements of the competent authority of the country of manufacturing.”
4.1.3.8.2 Replace „consignment note” with:
„transport document”.
4.1.4.1
P001 Insert a new row after „Composite packagings” to read as follows:
„Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met.”
Amend speciel packing provision PP2, to read as follows:
„PP2 For UN 3065, wooden barrels with a maximum capacity of 250 litres and which do not meet the provisions of Chapter 6.1 may be used.”
P002 Insert a new row after „Composite packagings” to read as follows:
„Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met.”
In special packing provisian PP37, armend the second sentence to read as follows:
„All bags of any type shall be carried in clased wagons or containers or be placed in closed rigid overpacks.”
P003 Add the following new special packing provisions:
„PP17 For UN Nos. 1950 and 2037, packages shall not exceed 55 kg net mass for fibreboard or 125 kg net mass for other packagings.
PP87 For UN 1950 waste aerosols carried in accordance with special provision 327, the packagings shall have a means of retaining any free liquid that might escape during carriage, e.g. absorbent material. The packaging shall be adequately ventilated to prevent the creation of flammable atmosphere and the build-up of pressure.
PP88 For UN 3473 when fuell cell cartridges are packed with equipment, they shall be packed in inner packagings or placed in the outer packaging with cushioning material so that the cartridges are protected against damage that may be caused by the movement or placement of the equipment and the cartridges within the outer packaging.”
Add a new row at the end to read as follows:
„Special packing provision specific to RID and ADR | ||
RR6 | For UN 1950 and 2037, in the case of carriage by wagon load or full load, metal articles may also be packed as follows: The articles shall be grouped together in units an trays and held in position with an appropriate plastics cover; these units shall be stacked and suitably secured on pallets.” |
P101 In the Note, replace „consignment note” with:
„transport document”.
P200 In paragraph (5)(b), in the sentence preceding the first equation, replace „gases for which data are not provided in the table” with:
„gases and gas mixtures for which relevant data are not available”.
In paragraph (5)(c), in the sentence before the equation, replace „gases for which filling data are not provided in the table” with:
„gases and gas mixtures for which relevant data are not available”.
In paragraph (10), amend special provisions „k”, l”, „n”, „p” and „z” as follows:
k: Add the following text before the third paragraph:
„Bundles containing UN 1045 Fluorine, compressed, may be constructed with isolation valves on assemblies (groups) of cylinders not exceeding 150 litres total water capacity instead of isolation valves on every cylinder.
Cylinders and individual cylinders wthin a bundle shall have a test pressure greater than or equal to 200 bar and a minimum wall thickness of 3.5 mm for aluminium alloy or 2 mm for steel. Individual cylinders not complying with this requirement shall be carried in a rigid outer packaging that will adequately protect the cylinder and its fittings and meeting the packing group I performance level. Pressure drums shall have a minimum wall thickness as specified by the competent authority.”
l: In the last sentence, replace „total quantity” with:
„maximum net mass”.
n: Amend to read as follows:
For UN 2190, oxygen difluoride, compressed, cylinders and individual cylinders within a bundle shall contain not more than 5 kg of the gas.
For UN 1045 fluorine, compressed, cylinders, individual cylinders within a bundle and assemblies of cylinders within a bundle shall contain not more than 5 kg of the gas. Bundles containing this gas may be divided in assemblies (groups) of cylinders not exceeding 150 litres total water capacity.”
p: In the first and third sub-paragraph, replace „porous mars” with „porous material”.
z: Amend the third paragraph to read as follows:
„Toxic substances with an LC50 less than or equal to 200 ml/m3 shall not be carried in tubes, pressure drums or MEGCs and shall meet the requirements of speciel packing provision „k”. However, UN 1975 Nitric oxide and dinitrogen tetroxide mixture may be carried in pressure drums.”
In Column „Reference” of the table in paragraph (11), add „+ A1:2005” after „EN 13365:2002”.
[In the Table in paragraph (11), add the following rows:
Applicable requirements | Reference | Title of document | |
(7) | EN 1439:2005 (except 3.5 and Annex C) | LPG equipment and accessories - Transportable refillable welded and brazed steel Liquefied Petroleum Gas (LPG) cylinders - Procedures for checking before, during and after filling | |
(7) | EN 14794:2005 | LPG equipment and accessories - Transportable refillable aluminium cylinders for liquefied petroleum gas (LPG) - Procedure for checking before, during and after filling |
]
In Tables 1 and 2, delete the entries for the following UN Nos.:
1014, 1015, 1979, 1980, 1981 and 2600.
In Table 1, in the heading of column 11, replace „Working pressure, bar” with:
„Maximum working pressure, barb”.
In Table 2:
- For UN Nos. 2192 and 2199, add „q” (twice for UN No. 2199) in the column under the heading „Special packing provisions”.
- For UN No. 2451, delete „300” and „0.75” in the columns for „Test pressure” and „Filling ratio”, respectively.
In paragraph (11), a the title of standard „’EN 1801:1998”, replace „porous masses” with „porous materials”.
P204 Amend to read as fallows:
„(Deleted)”.
P400 Amend paragraph (1) to read as follows:
„(1) Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met. They shall be made of steel and shall be subjected to an initial test and periodic tests every 10 years at a pressure of not less than 1 MPa (10 bar, gauge pressure). During carriage, the liquid shall be under a layer of inert gas with a gauge pressure of not less than 20 kPa (0.2 bar).”
P401 and
P402 Amend paragraph (1) to read as follows:
„(1) Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met. They shall be made of steel and subjected to an initial test and periodic tests every 10 years at a pressure of not less than 0.6 MPa (6 bar, gauge pressure). During carriage, the liquid shall be under a layer of inert gas with a gauge pressure of not less than 20 kPa (0.2 bar).”
P403,
P404 and
P410 Insert a new row after „Composite packagings” to read as follows:
„Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met.”
P404 In the first sentence, delete: „2005”.
At the end of the first sentence, replace „3391, 3393 and 3461” with:
„3391 and 3393”.
P520 Under „Additional requirements” in „4.”, insert „(model No.1, see 5.2.2.2.2)” after „risk label”.
P601 and