Időállapot: közlönyállapot (2007.VII.5.)

2007. évi XCI. törvény - a Bernben, 1980. május 9-én kelt, Nemzetközi Vasúti Fuvarozási Egyezmény (COTIF) módosításáról szóló, Vilniusban elfogadott, 1999. június 3-án kelt Jegyzőkönyv C Függelék Melléklete módosításainak és kiegészítéseinek kihirdetéséről 2/8. oldal

Bk-249 Am-245
Cf-253 Cm-249”

(b) Insert „Ag-108m Ag-108” after: „Ru-106 Rh-106”.

Delete the entries for:

„Ce-134, La-134”;

„Rn-220, Po-216”;

„Th-226, Ra-222, Rn-218, Po-214”; and

„U-240, Np-240m”.

2.2.7.7.2.2 In the first sentence, delete:

„competent authority approval, or for international carriage;”.

Amend the beginning of the second sentence to read as follows:

„It is permissible to use an A2 value calculated using a dose coefficient for the appropriate lung absorption type as recommended by the International Commission on Radiological Protection, if the chemical forms of each radionuclide under both normal ... ”.

In the table:

- Amend the second entry in the first column to read:

„Alpha emitting nuclides but no neutron emitters are known to be present”.

- Amend the third entry in the first column to read:

„Neutron emitting nuclides are known to be present or no relevant data are available”.

2.2.7.8.4

(d) and (e) Add at the end:

„except undpr the provisions of 2.2.7.8.5”.

Add a new 2.2.7.8.5 to read:

2.2.7.8.5 In case of international carriage of packages requiring competent authority design or shipment approval, for which different approval types apply in the different countries concerned by the shipment, assignment to the category as required in 2.2.7.8.4 shall be in accordance with the certifcate of the country of origin of design.”

2.2.7.9.7 Insert „Chapter 1.10” in the fist of provisions which do not apply.

2.2.8.1.6 Amend the beginning of the first sentence of the second paragraph to read as follows:

„Liquids, and solids which may become liquid during carriage, which are judged not to cause ... ” (remainder of the sentence unchanged).

2.2.8.3 Under classification code „C2”, amend the neme of UN 1740 to read as follows:

„HYDROGENDIFLUORIDES, SOLID, N.O.S.”

Under classifcation code „CF1”, add at the beginning:

„3470 PAINT, CORROSIVE, FLAMMABLE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or

3470 PAINT RELATED MATERIAL, CORROSIVE, FLAMMABLE (including paint thinning or reducing compound)”.

Under classification code „CT1”, add at the beginning:

„3471 HYDROGENDIFLUORIDES SOLUTION, N.O.S.”.

2.2.9.1.14 Replace „61 °C” with:

„60 °C”.

2.2.9.2 Amend the second indent to read as follows:

„- Uncleaned empty containment vessels for apparatus such as transformers, condensers and hydraulic apparatus containing substances assigned to UN Nos. 2315, 3151, 3152 or 3432.”

2.2.9.3 Under classification code „M8”, amend the name for UN 3245 to read as follows:

„GENETICALLY MODIFIED MICROORGANISMS or GENETICALLY MODIFIED ORGANISMS”.

2.3.3.1.7,

2.3.3.1.8 and

2.3.6 Figure Replace „61 °C” with:

„60 °C”.

PART 3

Chapter 3.1

3.1.2.2 and

3.1.2.3 Replace „consignment note” with:

„transport document”.

Chapter 3.2

3.2.1 In the explanatory note for column (5), delete the second indent.

In the explanatory note for column (11), add the following NOTE at the end:

NOTE: If technically relevant, these special provisions are not only applicable to the portable tanks specified in column (10), but also to the portable tanks that may be used according to the table in 4.2.5.2.5.”

In the explanatory note for column (13), add the following NOTE at the end:

NOTE: If technically relevant, these special provisions are not only applicable to the tanks specified in column (12), but also to the tanks that may be used according to the hierarchies in 4.3.3.1.2 and 4.3.4.1.2.”

In the explanatory note for column (13), delete the Note in the first and third indents.

Table A

Amend Table A as follows:

Replace the code „LQ19” with „LQ7” wherever it is listed in Column (7), except in the case of UN 2809.

(applies to UN Nos. 1556, 1583, 1591, 1593, 1597, 1599, 1602, 1656, 1658, 1686,
1710, 1718, 1719, 1731, 1755, 1757, 1760, 1761, 1783, 1787, 1788, 1789, 1791,
1793, 1805, 1814, 1819, 1824, 1835, 1840, 1848, 1851, 1887, 1888, 1897, 1902,
1903, 1908, 1935, 1938, 2021, 2024, 2030, 2205, 2206, 2209, 2225, 2235, 2269,
2272, 2273, 2274, 2279, 2289, 2290, 2294, 2299, 2300, 2311, 2320, 2321, 2326,
2327, 2328, 2431, 2432, 2433, 2470, 2491, 2496, 2501, 2504, 2511, 2515, 2518,
2525, 2533, 2564, 2565, 2580, 2581, 2582, 2586, 2609, 2656, 2661, 2664, 2667,
2669, 2672, 2677, 2679, 2681, 2688, 2689, 2693, 2730, 2732, 2735, 2739, 2747,
2753, 2785, 2788, 2790, 2801, 2810, 2815, 2817, 2818, 2819, 2820, 2821, 2829,
2831, 2837, 2849, 2872, 2873, 2874, 2902, 2903, 2904, 2922, 2937, 2941, 2942,
2946, 2991, 2992, 2993, 2994, 2995, 2996, 2997, 2998, 3005, 3006, 3009, 3010,
3011, 3012, 3013, 3014, 3015, 3016, 3017, 3018, 3019, 3020, 3025, 3026, 3055,
3066, 3140, 3141, 3142, 3144, 3145, 3172, 3264, 3265, 3266, 3267, 3276, 3278,
3280, 3281, 3282, 3287, 3293, 3320, 3347, 3348, 3351, 3352, 3410, 3411, 3413,
3414, 3415, 3418, 3421, 3422, 3424, 3426, 3429, 3434, 3435 and 3440)

Delete the code „TE15” wherever it is listed in Column (13).

In column (13), delete footnote * everywhere it appears in relation to special provisions „TU38” and „TE22”.

In column (13) insert „TE25” against ttre following entries:

- Tanks for gases of Class 2 with classification codes containing the letters T, TF, TC, TO, TFC or TOC,

- Tanks for substances of classes 3 to 8 with tank cade L15CH, L15DH or L21DH.

UN No. Column Amendment
1267, 1268 and 3295 Delete the entries for which „640P” is assigned in column (6)
1267, 1268 and 3295 6 For each entry that is currently assigned „640A” in column (6), insert: „649”.
1133, 1139, 1189, 1197, 1210, 1263, 1266, 1267, 1268, 1286, 1287, 1308, 1863, 1866, 1989, 1993, 2059 and 3295 2 Delete „(vapour pressure at 50 °C more than 175 kPa)” for each entry that is assigned „640A” in column (6).
6 Delete „640A” for each entry that is assigned „640A” in column (6).
1133, 1139, 1169, 1197, 1210, 1263, 1266, 1267, 1268, 1286, 1287, 1308, 1863, 1866, 1989, 1993, 2059 and 3295 Delete the entries for which „6408” is assigned in column (6).
1133, 1139, 1169, 1197, 1210, 1224, 1263, 1266, 1267, 1268, 1286, 1287, 1306, 1308, 1883, 1866, 1987, 1989, 1993, 1999, 3295 and 3336 2 Delete „but not more than 175 kPa” for each entry that is assigned „640C” in column (6).
1133, 1139, 1169, 1197, 1210, 1263, 1266, 1266, 1287, 1306, 1866, 1993 and 1999 2 For each entry that is assigned „640F” in column (6) replace „vapour pressure at 50 °C more than 175 kPa” with „boiling point not more than 35 °C”.
1133, 1139, 1169, 1197, 1210, 1263, 1266, 1286, 1287, 1306, 1866, 1993 and 1999 2 For each entry that is assigned „640G” in column (6) replace „but not more than 175 kPa” with „boiling point of more than 35 °C”.
UN No. Column Amendment
0015 6 Delete: „204”.
0016 6 Delete: „204”.
0303 6 Delete: „204”.
1013 6 Add: „653”.
1014 1-20 Delete the whole entry.
1015 1-20 Delete the whole entry.
1143 2 Amend the name to read as follows: „CROTONALDEHYDE or CROTONALDEHYDE, STABILIZED”.
6 Add „324”.
1155 12 Replace „L1.5BN” with; „L4BN”.
1167 12 Replace „L1.5BN” with: „L4BN”.
1169, PG II and III 6 Insert: „601” (six times).
1170, PG II and III 6 Insert: „330 601” (twice).
9 Delete: „PP2” (twice).
1197, PG II and III 6 Insert: „601” (six times).
1202 (first and third entry) 2 Replace „61 °C” with: „60 °C”.
1202 (second entry) 2 Replace „EN 590:1993” with: „EN 590:2004” (twice).
1203 (9a) Insert „BB2” adjacent to „IBC02” in column (8).
1218 12 Replace „L1.5BN” with: „L4BN”.
1219 6 Insert: „601”.
1263, VG I 11 Add: „TP27”.
1263, VG II 11 Add: „TP28” (twice).
1263, VG III 11 Add: „TP29” (twice).
1280 12 Replace „L1.5BN” with: „L4BN”.
1293, PG II and III 6 Insert: „601” (twice).
1302 12 Replace „L1.58N” with: „L4BN”.
1366 1-20 Delete the whole entry.
1370 1-20 Delete the whole entry.
1391 2 Add, at the end: „having a flash-point above 60 °C”.
6 Delete: „282„
1463 3b Replace „OC2” with: „OTC”.
5 Replace „5.1 + 8” with: „5.1 + 6.1 + 8”.
16 Insert: „W11 W12”.
18 After „CW24”, add: „CW28”.
20 Replace „58” with: „568”.
1614 8 Insert before „P601„: „PO99”.
1649 2 Add, at the end: „having a flash-point above 60 °C”.
6 Delete: „162”.
1733 10 Insert: „T3”.
11 Insert: „TP33”.
1740 2 Amend the name to read as follows: „HYDROGENDIFLUORIDES SOLID N.O.S,” (twice).
1779 2 Amend the name to read as follows: „FORMIC ACID with more than 85% acid by mass”.
3b Replace „C3” with; „CF1”.
5 After „8”, add; „+3”.
20 Replace „80” with: „83”.
1848 2 Amend the name to read as follows: „PROPIONIC ACID with not less than 10% and less than 90% acid by mass”.
1950 6 After „190”, insert: „327” (twelve times).
8 Replace „P204” with: „P003 LP02” (twelve times).
9a Insert: „PP17 PP87 RR6 L2” (twelve times).
16 Insert: „W14”.
1956 6 After „274”, insert: „292”.
1979 1-20 Delete the whole entry.
1980 1-20 Delete the whole entry.
1981 1-20 Delete the whole entry.
1987 PG I and III 6 Insert: „330 601” (three times).
1993 PG I, II and III 6 Insert: „330” (seven times).
1993, PG II and III 6 Insert: „601” (six times).
2005 1-20 Delete the whole entry.
2015 10 Replace „T10” with: „T9” (twice).
2030 2 Add, at the end: „having a flash-point above 60 °C” (three times).
6 Delete: „298” (three times).
2030, PG I 10 Replace „T20” with: „T10”.
2030, PG II 10 Replace „T15” with: „T7”.
2030, PG III 11 Replace „TP2” with: „TP1”.
2037 8 Replace „P204„’ with: „P003” (nine times).
9a Add: „PP17 RR6” (nine times).
2356 12 Replace „L1.5BN” with: „L4BN”.
2363 12 Replace „L1.5BN” with: „L4BN”.
2445 1-20 Delete the whole entry.
2600 1-20 Delete the whole entry.
2662 1-20 Delete the whole entry.
2814 6 Delete: „634”.
2823 2 Amend the name to read as follows: „CROTONIC ACID SOLID”.
2880, PG II 6 Add: „322”.
2880, PG III 6 Replace „316” with: „313 314”.
2900 6 Delete: „634”.
10 Delete: „BK1 BK2”.
2912 6 Add: „325”.
2915 6 Add: „325”.
3051 1-20 Delete the whole entry.
3052 1-20 Delete the whole entry.
3053 1-20 Delete the whole entry.
3066, PG II 11 Add: „TP28”.
3066, PG III 11 Add: „TP29”.
3076 1-20 Delete the whole entry.
3077 6 Insert: „601”.
3082 6 Insert: „601”.
3175 2 Replace „61 °C” with: „60 °C”.
3245 2 Amend the name to read as follows: „GENETICALLY MODIFIED MICROORGANISMS or GENETICALLY MODIFIED ORGANISMS”.
6 Delete: „634”.
3256 2 Replace „61 °C” with: „60 °C”.
13 Delete: „TE24”.
3257 13 Delete: „TE24”.
3272, PG II and III 6 Insert: „601” (twice).
3291 6 Delete: „634”.
10 Add: „BK2”.
3321 6 Add: „325”.
3322 6 Add: „325”.
3324 6 Add: „326”.
3325 8 Add: „326„
3327 6 Add: „326”.
3336 12 Replace „L1.5BN” with: „L4BN”.
3364, 3365, 3366, 3367, 3368, 3370 2 Replace „wetted” with: „WETTED”.
3373 2 Amend the name to read as follows: „BIOLOGICAL SUBSTANCE, CATEGORY B”.
5 Insert: „6.2”.
10 Insert: „T1.”.
11 Insert: „TP1”.
3375, liquid 13 Delete: „TU26’”.
3375, solid 13 Delete: „TU26”.
3433 1-20 Delete the whole entry.
3435 1-20 Delete the whole entry.
3461 1-20 Delete the whole entry.

Add the following new entries:

Packaging Portable tanks and bulk containers RID tanks Special provisions for carriage
Un No. Name and description Class Clas-
sifi-
cation code
Pac-
king gruop
La-
bels
Spe-
cial pro-
visi-
ons
Limi-
ted quan-
titites
Pac-
king in-
druc-
tions
Spe-
cial pac-
king pro-
visi-
ons
Mi-
xed pack. pro-
visi-
ons
Inst-
ruc-
tions
Spe-
cial pro-
visi-
ons
Tank code Spe-
cial pro-
visi-
ons
Ve-
hicle for tank carri-
age (ADR)
Tran-
sport cate-
gory
Pac-
kages
Bulk Load-
ing, un-
load-
ing and handl-ing
Ope-
ration (ARD)
Colis
ex-
pres
Ha-
zard
iden-
tificat
ion No.
(1) (2) (3a) (3b) (4) (5) (6) (7) (8) (9a) (9b) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (19) (20)
0015 AMMUNITION, SMOKE with or without burster, expelling charge or propelling charge, containing corrosive substances 1 1.2G 1+8 LQ0 P130 LP
101
PP67
L1
MP23 1 W2 CW1 1.2G
0016 AMMUNITION, SMOKE with or without burster, expelling charge or propelling charge, containing corrosive substances 1 1.3G 1+8 LQ0 P130
LP
101
PP67
L1
MP23 1 W2 CW1 1.3G
0303 AMMUNITION, SMOKE with or without burster, expelling charge or propelling charge, containing corrosive substances 1 1.4G 1.4+8 LQ0 P130 LP
101
PP67
L1
MP23 2 W2 CW1 1.4G
1391 ALKALI METAL DISPERSION or ALKALINE EARTH METAL DISPERSION having a flash-point of not more than 60 °C 4.3 WF1 1 4.3+3 182
183
274
506
LQ0 P402 PR1 MP2 L10
BN
(+)
TU1
TE5
TT3
TM2
1 W1 CW
23
X323
1649 MOTOR FUEL ANTI-KNOCK MIXTURE having a flash-
point of not more than 60 °C
6.1 TF1 1 6.1+3 LQ0 P602 MP8 MP17 T14 TP2 L10
CH
TU14
TU15
TU38
TE21
TE22
TT6
1 CW
13 CW
28 CW
31
663
2030 HYDRAZINE AQUEOUS SOLUTION, with more than 37% hydrazine by mass having a fiash-point of not more than 60 °C 8 CFT 1 8+6.1+3 530 LQ0 P001 MP8 MP17 T10 TP2 L10
BH
TU38 TE22 1 CW
13 CW
28
886
2814 INFECTIOUS SUBSTANCE, AFFECTING HUMANS, in refrigerated liquid nitrogen 6.2 I1 6.2+
2.2
318 LQ0 P620 MP5 0 W9 CW
13 CW
18 CW
26 CW
28
CE14 606
2814 INFECTIOUS SUBSTANCE, AFFECTING HUMANS (animal carcasses only) 6.2 I1 6.2 318 LQ0 P099 P620 MP5 BK1 BK2 0 W9 CW
13 CW
18 CW
26 CW
28
CE14 606
2900 INFECTIOUS SUBSTANCE, AFFECTING ANIMALS only, in refrigerated liquid nitrogen 6.2 I2 6.2+
2.2
318 LQ0 P620 MP5 0 W9 CW
13 CW
18 CW
26 CW
28
CE14 606
2900 INFECTIOUS SUBSTANCE, AFFECTING ANIMALS only (animal carcasses and wastes only) 6.2 I2 6.2 318 LQ0 P099 P620 MP5 BK1
BK2
0 W9 CW
13 CW
18 CW
26 CW
28
CE14 606
3245 GENETICALLY MODIFIED MICROORGANISMS or GENETICALLY MODIFIED ORGANISMS, in refigerated liquid nitrogen 9 M8 9+2.2 219 637 LQ0 P904 IBC
08
MP6 2 CW
13
C17
CW
18
CW
26
GW
28
CW
31
90
3291 CLINICAL WASTE, UNSPECIFIED, N.O.S. or (BIO) MEDICAL WASTE, N.O.S. or REGULATED MEDICAL WASTE, N.O.S., in refrigerated liquid nitrogen 6.2 I3 II 6.2+
2.2
565 LQ0 P621 IBC
620 LP
621
MP6 2 W9 CW
13
CW
18
CW
28
CE14 606
3412 FORMIC ACID with not less than 10% but not more than 85% acid by mass 8 C3 II 8 LQ22 P001 IBC
02
MP15 T7 TP2 L4BN 2 CE6 80
3412 FORMIC ACID with not less than 5% but less than 10% acid by mass 8 C3 III 8 LQ7 P001
IBC
03
LP01
R001
MP15 T4 TP1 L4
BN
3 CE6 80
3463 PROPIONIC ACID with not less than 90% acid by mass 8 CF1 II 8+3 LQ22 P001 IBC02 MP15 T7 TP2 L4
BN
2 CE6 83
3469 PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL, FLAMMABLE, CORROSIVE (including paint thinning or reducing compound) 3 FC I 3+8 163 LQ3 P001 MP7
MP17
T11 TP2
TP27
L10
CH
TU14
TU38
TE21
TE22
1 338
3469 PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAL, FLAMMABLE, CORROSIVE (including paint thinning or reducing compound) 3 FC II 3+8 163 LQ4 P001
IBC
02
MP19 T7 TP2
TP8
TP8
L48H 2 CE7 338
3469 PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAI, FLAMMABLE, CORROSIVE (including paint thinning or reducing compound) 3 FC III 3+8 163 LQ7 P001
IBC
03 R001
MP19 T4 TP1
TP29
L48H 2 CE4 38
3470 PAINT, CORROSIVE, FLAMMABLE (incliding paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) or PAINT RELATED MATERIAI, CORROSIVE, FLAMMABLE (including paint thinning or reducing compound) 8 CF1 II 8+3 163 LQ22 P001
IBC
02
MP15 T7 TP2 TP8 TP28 L4
BN
2 CE6 83
3471 HYDROGENDI-
FLUORIDES SOLUTION, N.O.S.
8 CT1 II 8+6.1 LQ22 P001
IBC
02
MP15 T7 TP2 L4
DH
TU14 TE17 TE21 TT4 2 CW
13 CW
28
CE6 86
3471 HYDROGENDI-
FLUORIDES SOLUTION, N.O.S.
8 CT1 III 8+6.1 LQ7 P001
IBC
03 R001
MP15 T4 TP1 L4
DH
TU14 TE21 3 CW
13 CW
28
CE8 86
3472 CROTONIC ACID, LIQUID 8 C3 III 8 LQ7 P001 IBC
03 LP01
R001
MP15 T4 TP1 L4
BN
3 CE8 80
3473 FUEL CELL CARTRIDGES containing flammable liquids 3 F1 3 328 LQ13 P003 PP88 3 CE7 30

Table B

Name and description UN No. Amendment
ALUMINIUM ALKYLS 3051 Delete.
ALUMINIUM ALKYL HALIDES, SOLID 3461 Delete.
ALUMINIUM ALKYL HALIDES, LIQUID 3052 Delete.
ALUMINIUM ALKYL HIDRIDES 3076 Delete.
CARBON DIOXIDE AND NITROUS OXIDE MIXTURE 1015 Delete.
CARBON DIOXIDE AND OXYGEN MIXTURE, COMPRESSED 1014 Delete.
CARBON MONOXIDE AND HYDROGEN MIXTURE, COMPRESSED 2600 Delete.
CLINICAL SPECIMENS 3373 Delete.
CROTONIC ACID 2823 Amend the name to read as follows: „CROTONIC ACID SOLID”.
DIAGNOSTIC SPECIMENS 3373 Amend the name to read as follows: „BIOLOGICAL SUBSTANCE, CATEGORY B”.
DIETHYLZINC 1366 Delete.
DIMETHYLZINC 1370 Delete.
ELEVATED TEMPERATURE LIQUID, FLAMMABLE, N.O.S. with flash-point above
61 °C, at or above its flash-point
3256 Replace „61 °C” with: „60 °C”.
Fischer Tropsch gas: see 2600 Delete.
FORMIC ACID 1779 Amend the name to read as follows: „FORMIG ACID with more than 85% acid by mass”.
GENETICALLY MODIFIED MICRO-ORGANISMS 3245 Amend the name to read as follows: „GENETICALLY MODIFIED MIGROORGANISMS”. In Column „NHM-Code” replace „051199” with: „300290”.
GENETICALLY MODIFIED ORGANISMS In Column „UN No.”, insert: „3245”.
HYDROGENDIFLUORIDES, N.O.S. 1740 Amend the name to read as follows: „HYDROGENDIFLUORIDES, SOLID N.O.S.”.
HYDROQUINONE, SOLID 2662 Delete.
HYDROQUINONE SOLUTION 3435 Delete.
LITHIUM ALKYLS, SOLID 3433 Delete.
LITHIUM ALKYLS, LIQUID 2445 Delete.
MAGNESIUM ALKYLS 3053. Delete.
MAGNESIUM DIPHENYL 2005 Delete.
Mixtures of solids containing flammable liquid, n.o.s. having a flash-point up to 61 °C 3175 Replace „61 °C” with: „60 °C”.
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) 1263 In Column „NHM-Code”, delete: °381400”.
PAINT (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) 3066 In Column „NHM-Code”, delete: „381400”.
PAINT RELATED MATERIAL (including paint thinning or reducing compound) 1263 In Calumn „NHM-Code”, delete: „3208++”.
PAINT RELATED MATERIAL (including paint thinning or reducing compound) 3066 In Column „NHM-Code”, delete: „3208++”.
PICRIC ACID wetted with not less than 10% water, by mass 3364 Replace „wetted” with: „WETTED”.
PICRYL CHLORIDE wetted with not less than 10% water, by mass 3365 Replace „wetted” with: „WETTED”.
Preparations containing flammable liquid, n.o.s. having a flash-point up to 61 °C 3175 Replace „61 °C” with: „60 °C”.
PROPIONIC ACID 1848 Amend the name to read as follows: „PROPIONIC ACID with not less than 10% and less than 90% acid by mass”.
RARE GASES AND NITROGEN MIXTURE COMPRESSED 1981 Delete.
RARE GASES AND OXYGEN MIXTURE COMPRESSED 1980 Delete.
RARE GASES, MIXTURE, COMPRESSED 1979 Delete.
SOLIDS CONTAINING FLAMMABLE LIQUID, N.O.S. having a flash-point up to 61 °C 3175 Replace „”61 °C” with: „60 °C”.
Synthesis gas: see 2600 Delete.
TNT, wetted with not less than 10% water, by mass 3366 Replace „wetted” with: „WETTED”.
TRINITROBENZENE, wetted with not less than 10% water, by mass 3367 Replace „wetted” with: „’WETTED”.
TRINITROBENZOIC ACID, wetted with not less than 10% water, by mass 3368 Replace „wetted” with: „WETTED”.
TRINITROGHLOROBENZENE wetted with not less than 10% water, by mass 3365 Replace „wetted” with: „WETTED”.
TRINITROPHENOL wetted with not less than 10% water, by mass 3364 Replace „wetted” with: „WETTED”.
TRINITROTOLUENE, wetted with not less than 10% water, by mass 3366 Replace „wetted” with: „’WETTED”.
UREA NITRATE, wetted with not less than 10% water, by mass 3370 Replace „wetted” with: „WETTED”.
Wastes containing flammable liquid, n.o.s. having a flash-point up to 61 °C 3175 Replace „61 °C” with: „60 °C”.
Water gas: see 2600 Delete.

Add the following new entries:

Name and description UN No. Note NHM-Code
CROTONALDEHYDE 1143 291219
CROTONIC ACID, LIQUID 3472 291619
FORMIC ACID with not less than 10% but not more than 85% acid by mass 3412 291511
FUEL CELL CARTRIDGES containing flammable liquids 3473 850680
HYDROGENDIFLUORIDES SOLUTION, N.O.S. 3471 282619
PAINT, CORROSIVE, FLAMMABLE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) 3470 3208++
PAINT, FLAMMABLE, CORROSIVE (including paint, lacquer, enamel, stain, shellac, varnish, polish, liquid filler and liquid lacquer base) 3469 3208++
PAINT RELATED MATERIAL, CORROSIVE, FLAMMABLE (including paint thinning or reducing compound) 3470 381400
PAINT RELATED MATERIAL, FLAMMABLE, CORROSIVE (including point thinning or reducing compound) 3469 381400
PROPIONIC ACID with not less than 90% acid by mass 3463 291550

Chapter 3.3

3.3.1

SP 250 (b),

SP 318,

SP 581,

SP 582,

SP 583,

SP 640 and

SP 650 (e) Replace „consignment note” with:

„transport document”.

SP 162 Replace current text with:

„(Deleted)”.

SP 181 Insert „(see 5.2.2.2.2) „after „model No.1”.

SP 204 Replace current text with:

„(Deleted)”.

SP 216 In the last sentence, insert „and articles” before „containing” and amend the end to read: ”... free liquid in the packet or article.”

SP 247 Amend the end of the first paragraph to read:

”... may be carried in wooden barrels with a capacity of more than 250 litres and not more than 500 litres meeting the general requirements of 4.1.1, as appropriate, on the following conditions: ...”.

Replace the word „casks” with „wooden barrels” (5 times).

SP 251 In the first sentence, add „for example” before „for medical,” add „or repair” before „purposes”.

SP 282 Replace current text with:

„(Deleted)”.

SP 289 Replace „vehicles” and „vehicle” with „conveyances” and „conveyance”, respectively.

SP 292 Amend to read as follows:

„Mixtures containing not more than 23.5% oxygen by volume may be carried under this entry when no other oxidizing gases are present. A label conforming to model 5.1 is not required for any concentrations within this limit.”

SP 298 Replace current text with:

„(Deleted)”.

SP 303 Amend to read as follows:

„Receptacles shall be assigned to the classification code of the gas or mixture of gases contained therein determined in accordance with the provisions of section 2.2.2.”

SP 309 Amend to read as follows:

„This entry applies to nan sensitized emulsions, suspensions and gels consisting primarily of a mixture of ammonium nitrate and fuel, intended to produce a Type E blasting explosive only after further processing prior to use.

The mixture for emulsions typically has the following composition: 60-85% ammonium nitrate, 5-30% water, 2-8% fuel, 0.5-4% emulsifier agent, 0-10% soluble flame suppressants, and trace additives. Other inorganic nitrate salts may replace part of the ammonium nitrate.

The mixture for suspensions and gels typically has the following composition: 60-85% ammonium nitrate, 0-5% sodium or potassium perchlorate, 0-17% hexamine nitrate or monomethylamine nitrate, 5-30% water, 2-15% fuel, 0.5-4% thickening agent, 0-10% soluble flame suppressants, and trace additives. Other inorganic nitrate salts may replace part of the ammonium nitrate.

Substances shall satisfactarily pass Test Series 8 of the Manual of Tests and Criteria, Part I, Section 18 and be approved by the competent authority.”.

SP 316 Delete „or hydrated”.

SP 319 Delete the first sentence.

SP 320 Amend to read as follows:

„(Deleted)”,

322-499 (Reserved)” becomes:

331-499 (Reserved)”.

SP 601 Amend to read as follows:

„Pharmaceutical products (medicines) ready for use, which are substances manufactured and packaged for retail sale or distribution for personal or household consumption are not subject to the requirements of RID.”

SP 617 Delete:

„and shall be specified in the consignment note”.

SP 633 Amend „unless any international tariffs or agreements between the railways provide otherwise” to read:

„unless any agreements concluded between the countries concerned in the transport operation provide otherwise”.

SP 634 Amend to read as follows:

„(Deleted)”.

SP 645 Add the following new sentence at the end:

„When assignment to a division is made in accordance with the procedure in 2.2.1.1.7.2, the competent authority may require the default classification to be verified on the basis of test data derived from Test Series 6 of the Manual of Tests and Criteria, Part I, Section 16.”

SP 649 Delete the address in footnote 2.

Add the following new special provisions:

322 When carried in non-friable tablet form, these goods are assigned to packing group III.

323 (Reserved)

324 This substance needs to be stabitized when in concentrations of not more than 99%.

325 In the case of non-fissile or fissile excepted uranium hexafluoride, the material shall be classified under UN No. 2978.

326 In the case of fissile uranium hexafluoride, the material shall be classified under UN No. 2977.

327 Waste aerosols consigned in accordance with 5.4.1.1.3 may be carried under this entry for the purposes of reprocessing or disposal. They need nat be protected against inadvertent discharge provided that measures to prevent dangerous build up of pressure and dangerous atmospheres are addressed. Waste aerosols, other than those leaking or severely deformed, shall be packed in accordance with packing instruction P003 and special provision PP87, or packing instruction LP02 and special packing provision L2. Leaking or severely deformed aerosols shall be carried in salvage packagings provided appropriate measures are taken to ensure there is no dangerous build up of pressure.

NOTE: For maritime carriage, waste aerosols shall not be carried in closed containers.

328 This entry applies to fuel cell cartridges containing flammable liquids including methanol or methanol/water solutions. Fuel cell cartridge means a container that stores fuel for discharge into fuel cell powered equipment through a valve(s) that controls the discharge of fuel into such equipment and is free of electric charge generating components. The cartridge shall be designed and constructed to prevent the fuel from leaking during normal conditions of carriage.

This entry applies to fuel cell cartridge design types shown without their packaging to pass an internal pressure test at a pressure of 100 kPa (gauge).

329 (Reserved)

330 Alcohols containing petroleum products (e.g. gasoline) up to 5% shall be carried under the entry UN 1987 ALCOHOLS, N.O.S.

653 The carriage of this gas in cylinders with a maximum capacity of 0.5 litres, is not subject to the other provisions of RID if the following conditions are met:

- The provisions for construction and testing of cylinders are observed;

- The cylinders are contained in outer packagings which at least meet the requirements of Part 4 for combination packagings. The general provisions of packing of 4.1.1.1, 4.1.1.2 and 4.1.1.5 to 4.1.1.7 shall be observed;

- The cylinders are not packed together with other dangerous goods;

- The total gross mass of a package does not exceed 30 kg; and

- Each package is clearly and durably marked with „UN 1013”. This marking is displayed within a diamond-shaped area surrounded by a line that measures at least 100 mm by 100 mm.”

Chapter 3.4

3.4.6 In the first column of table 3.4.6 replace „LQ4” and „LQ5” with „LQ4” and „LQ5” respectively,

In the table, for LQ19, replace respectively „3 /” and „1 /” with „5 kg”.

PART 4

Chapter 4.1

4.1.1.2 In the Note, delete „high and medium molecular mass”.

4.1.1.3 Replace „6.5.4” with:

„6.5.6”.

4.1.1.5 Insert the following new second sentence:

„Inner packagings containing liquids shall be packed with their closures upward and placed within outer packagings consistent with the orientation markings prescribed in 5.2.1.9.”

4.1.1.5.1 Insert a new paragraph 4.1.1.5.1 with the same text as in existing 6.1.5.1.6 with the insertion of the words „or a large packaging” after „combination packaging” and the words „or large packaging” after „outer packaging” in the first sentence.

4.1.1.8 Amend to read as follows:

4.1.1.8 Where pressure may develop in a package by the emission of gas from the contents (as a result of temperature increase or other causes), the packaging or IBC may be fitted with a vent provided that the gas emitted will not cause danger on account of its toxicity, its ftammability or the quantity released, far example.

A verting device shall be fitted if dangerous overpressure may develop due to normal decomposition of substances. The vent shall be so designed that, when the packaging or IBC is in the attitude in which it is intended to be carried, leakages of liquid and the penetration of foreign substances are prevented under normal conditions of carriage.

NOTE: Verting of the package is not permitted for air carriage.

4.1.1.8.1 Liquids may only be filled into inner packagings which heve an appropriate resistance to internal pressure that may be developed under honnal conditions of carriage.”

4.1.1.9 Replace „6.5.4” with:

„6.5.6”.

4.1.1.12 In the first sentence, replace ”, including IBCs,” with „as specified in Chapter 6.1” and delete”, or 6.5.4.7 for the various types of IBCs”.

Delete (c).

In the lest paragraph, delete”, or IBC,” in the first sentence and „or IBC” in the second sentence.

4.1.1.18.1 Add at the end:

„and 4.1.1.18.3”.

Add a new paragraph to read as follows:

4.1.1.18.3 Appropriate measures shall be taken to ensure that there is no dangerous build up of pressure.”

4.1.1.19.1 In the first sentence, delete „high and medium molecular mass” and „high molecular mass”.

In the first sentence, replace „6.5.4.3.5” with:

„6.5.6.3.5”.

In the first sentence, replace „6.5.4” with:

„6.5.6”.

In the second sentence, replace „6.5.4.3.3 or 6.5.4.3.6” with:

„6.5.6.3.3 or 6.5.6.3.6”.

4.1.1.19.2 Replace „6.5.4.1.3” with:

„6.5.6.9.4”.

Replace „6.5.4.6” with:

„6.5.6.6”.

Replace „6.5.4.8.4.2” with:

„6.5.6.8.4.2”.

4.1.1.19.3 (c) and (d) Replace „6.5.4.3.3 or 6.5.4.3.6” with:

„6.5.6.3.3 or 6.5.6.3.6”.

4.1.1.19.6 Make the following modifications in Column (2b) of the Table:

- For UN numbers 1198, 1760, 1835, 1920, 2324, 2357, 2394, 2617, 2620, 2656, 2683, 2850, 2920 (three times), 2922, 3082 (seven times), 3264, 3265, 3266, 3267 and 3271, replace „61 °C” with:

„60 °C”.

- For UN No. 1202, replace „EN 590:1993” with:

„EN 590:2004” (twice).

- Amend the name for UN No. 1779 to read as follows:

„FORMIC ACID with more than 85% acid by mass”.

- In the table, in Note * to UN No. 1791, replace „For hypochlorite solutions” with:

„If the test is carried aut with hypochlorite solutions themselves”.

- Amend the name for UN No. 1848 to read as follows:

„PROPIONIC ACID with not less than 10% and less than 90% acid by mass”.

4.1.2.1 Replace „61 °C” with:

„60 °C”.

4.1.2.2 Replace the first sentence with the following paragraph:

„Every metal, rigid plastics and composite IBC, shall be inspected and tested, as relevant, in accordance with 6.5.4.4 or 6.5.4.5.

(a) before it is put into service;

(b) thereafter at intervals not exceeding two and a half and five years, as appropriate;

(c) after the repair or remanufacture, before it is re-used for carriage.”

Amend the end of the second sentence (starting with „An IBC shall not be filled ... ”) to read as follows: ”... expiry of the last periodic test or inspection.”

In the Note, replace „consignment note” with:

„transport document”.

4.1.3.6 Amend to read as follows:

4.1.3.6 Pressure receptacles for liquids and solids

4.1.3.6.1 Unless otherwise indicated in RID, pressure receptacles conforming to:

(a) the applicable requirements of Chapter 6.2 or

(b) the national or international standards on the design, construction, testing, manufacturing and inspection, as applied by the country in which the pressure receptacles are manufactured, provided that the provisions of 4.1.3.6 are met and that, for metallic cylinders, tubes, pressure drums and bundies of cylinders, the construction is such that the minimum burst ratio (burst pressure divided by test pressure) is:

(i) 1.50 for refillable pressure receptacles;

(ii) 2.00 for non-refillable pressure receptacles;

are authorized for the carriage of any liquid or solid substance other than explosives, thermally unstable substances, organic peroxides, self-reactive substances, substances where significant pressure may develop by evolution of chemical reaction and radioactive material (unless permitted in 4.1.9).

This sub-section is not applicable to the substances mentioned in 4.1.4.1, packing instruction P200, table 3 and in 4.1.4.4.

4.1.3.6.2 Every design type of pressure receptacle shall be approved by the competent authority of the country of manufacture or as indicated in Chapter 6.2.

4.1.3.6.3 Unless otherwise indicated, pressure receptacles having a minimum test pressure of 0.6 MPa shall be used.

4.1.3.6.4 Unless otherwise indicated, pressure receptacles may be provided with an emergency pressure relief device designed to avoid bursting in case of overfill or fire accidents.

Pressure receptacle valves shall be designed and constructed in such a way that they are inherently able to withstand damage without release of the contents or shall be protected from damage which could cause inadvertent release of the contents of the pressure receptacle, by one of the methods as given in 4.1.6.8 (a) to (f).

4.1.3.6.5 The level of filling shall not exceed 85% of the capacity of the pressure receptacle at 50 °C. Sufffcient ullage (outage) shall be left to ensure that the pressure receptacle will not be liquid full at a temperaturu of 55 °C.

4.1.3.6.6 Unless otherwise indicated pressure receptacles shall be subjected to a periodic inspection and test every 5 years. The periodic inspection shall include an external examination, an internal examination or altemative method as approved by the competent authority, a pressure test or equivalent effective non-destructive testing with the agreement of the competent authority including an inspection of all accessories (e.g. tightness of valves, emergency relief valves or fusible elements). Pressure receptacles shall not be filled after they become due for periodic inspection and test but may be carried after the expiry of the time limit. Pressure receptacle repairs shall meet the requinements of 4.1.6.11.

4.1.3.6.7 Prior to filling, the packer shall perform an inspection of the pressure receptacle and ensure that the pressure receptacle is authorized for the substances to be carried and that the requirements of RID have been met. Shut-off valves shall be closed after filling and remain closed during carriage. The consignor shall verify that the closures and equipment are not leaking.

4.1.3.6.8 Refillable pressure receptacles shall not be filled with a substance different from that previously contained unless the necessary operations for change of service heve been performed.

4.1.3.6.9 Marking of pressure receptacles for liquids and solids according to 4.1.3.6 (not conforming to the requirements of Chapter 6.2) shall be in accordance with the requirements of the competent authority of the country of manufacturing.”

4.1.3.8.2 Replace „consignment note” with:

„transport document”.

4.1.4.1

P001 Insert a new row after „Composite packagings” to read as follows:

Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met.”

Amend speciel packing provision PP2, to read as follows:

PP2 For UN 3065, wooden barrels with a maximum capacity of 250 litres and which do not meet the provisions of Chapter 6.1 may be used.”

P002 Insert a new row after „Composite packagings” to read as follows:

Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met.”

In special packing provisian PP37, armend the second sentence to read as follows:

„All bags of any type shall be carried in clased wagons or containers or be placed in closed rigid overpacks.”

P003 Add the following new special packing provisions:

PP17 For UN Nos. 1950 and 2037, packages shall not exceed 55 kg net mass for fibreboard or 125 kg net mass for other packagings.

PP87 For UN 1950 waste aerosols carried in accordance with special provision 327, the packagings shall have a means of retaining any free liquid that might escape during carriage, e.g. absorbent material. The packaging shall be adequately ventilated to prevent the creation of flammable atmosphere and the build-up of pressure.

PP88 For UN 3473 when fuell cell cartridges are packed with equipment, they shall be packed in inner packagings or placed in the outer packaging with cushioning material so that the cartridges are protected against damage that may be caused by the movement or placement of the equipment and the cartridges within the outer packaging.”

Add a new row at the end to read as follows:

„Special packing provision specific to RID and ADR
RR6 For UN 1950 and 2037, in the case of carriage by wagon load or full load, metal articles may also be packed as follows: The articles shall be grouped together in units an trays and held in position with an appropriate plastics cover; these units shall be stacked and suitably secured on pallets.”

P101 In the Note, replace „consignment note” with:

„transport document”.

P200 In paragraph (5)(b), in the sentence preceding the first equation, replace „gases for which data are not provided in the table” with:

„gases and gas mixtures for which relevant data are not available”.

In paragraph (5)(c), in the sentence before the equation, replace „gases for which filling data are not provided in the table” with:

„gases and gas mixtures for which relevant data are not available”.

In paragraph (10), amend special provisions „k”, l”, „n”, „p” and „z” as follows:

k: Add the following text before the third paragraph:

„Bundles containing UN 1045 Fluorine, compressed, may be constructed with isolation valves on assemblies (groups) of cylinders not exceeding 150 litres total water capacity instead of isolation valves on every cylinder.

Cylinders and individual cylinders wthin a bundle shall have a test pressure greater than or equal to 200 bar and a minimum wall thickness of 3.5 mm for aluminium alloy or 2 mm for steel. Individual cylinders not complying with this requirement shall be carried in a rigid outer packaging that will adequately protect the cylinder and its fittings and meeting the packing group I performance level. Pressure drums shall have a minimum wall thickness as specified by the competent authority.”

l: In the last sentence, replace „total quantity” with:

„maximum net mass”.

n: Amend to read as follows:

For UN 2190, oxygen difluoride, compressed, cylinders and individual cylinders within a bundle shall contain not more than 5 kg of the gas.

For UN 1045 fluorine, compressed, cylinders, individual cylinders within a bundle and assemblies of cylinders within a bundle shall contain not more than 5 kg of the gas. Bundles containing this gas may be divided in assemblies (groups) of cylinders not exceeding 150 litres total water capacity.”

p: In the first and third sub-paragraph, replace „porous mars” with „porous material”.

z: Amend the third paragraph to read as follows:

„Toxic substances with an LC50 less than or equal to 200 ml/m3 shall not be carried in tubes, pressure drums or MEGCs and shall meet the requirements of speciel packing provision „k”. However, UN 1975 Nitric oxide and dinitrogen tetroxide mixture may be carried in pressure drums.”

In Column „Reference” of the table in paragraph (11), add „+ A1:2005” after „EN 13365:2002”.

[In the Table in paragraph (11), add the following rows:

Applicable requirements Reference Title of document
(7) EN 1439:2005 (except 3.5 and Annex C) LPG equipment and accessories - Transportable refillable welded and brazed steel Liquefied Petroleum Gas (LPG) cylinders - Procedures for checking before, during and after filling
(7) EN 14794:2005 LPG equipment and accessories - Transportable refillable aluminium cylinders for liquefied petroleum gas (LPG) - Procedure for checking before, during and after filling

]

In Tables 1 and 2, delete the entries for the following UN Nos.:

1014, 1015, 1979, 1980, 1981 and 2600.

In Table 1, in the heading of column 11, replace „Working pressure, bar” with:

„Maximum working pressure, barb”.

In Table 2:

- For UN Nos. 2192 and 2199, add „q” (twice for UN No. 2199) in the column under the heading „Special packing provisions”.

- For UN No. 2451, delete „300” and „0.75” in the columns for „Test pressure” and „Filling ratio”, respectively.

In paragraph (11), a the title of standard „’EN 1801:1998”, replace „porous masses” with „porous materials”.

P204 Amend to read as fallows:

„(Deleted)”.

P400 Amend paragraph (1) to read as follows:

„(1) Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met. They shall be made of steel and shall be subjected to an initial test and periodic tests every 10 years at a pressure of not less than 1 MPa (10 bar, gauge pressure). During carriage, the liquid shall be under a layer of inert gas with a gauge pressure of not less than 20 kPa (0.2 bar).”

P401 and

P402 Amend paragraph (1) to read as follows:

„(1) Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met. They shall be made of steel and subjected to an initial test and periodic tests every 10 years at a pressure of not less than 0.6 MPa (6 bar, gauge pressure). During carriage, the liquid shall be under a layer of inert gas with a gauge pressure of not less than 20 kPa (0.2 bar).”

P403,

P404 and

P410 Insert a new row after „Composite packagings” to read as follows:

Pressure receptacles may be used provided that the general provisions of 4.1.3.6 are met.”

P404 In the first sentence, delete: „2005”.

At the end of the first sentence, replace „3391, 3393 and 3461” with:

„3391 and 3393”.

P520 Under „Additional requirements” in „4.”, insert „(model No.1, see 5.2.2.2.2)” after „risk label”.

P601 and